Table of contents
Component Details
The Allen Bradley 836P-N2NMGB14A-D4 is a precision pressure transmitter developed by Rockwell Automation’s Allen Bradley brand. It is part of the company’s portfolio of products for industrial automation and control. This model of pressure transmitter is notable for its features, which include:
- Accuracy: The Allen Bradley 836P-N2NMGB14A-D4 has a measurement accuracy of ±0.25% FS for absolute pressure and ±0.15% FS for gauge pressure.
- Rangeability: The transmitter can operate over a wide pressure range, typically from 0 to 60 bar (0 to 875 psi).
- Differential pressure measurement: The Allen Bradley 836P-N2NMGB14A-D4 can also measure the differential pressure between two points in a system.
- Digital communication: The transmitter supports digital communication protocols such as HART, DeviceNet, and PROFIBUS PA. This makes it easy to integrate into automation and control systems that use these protocols.
- Immunity to electromagnetic interference (EMI): The Allen Bradley 836P-N2NMGB14A-D4 is designed to withstand electromagnetic interference, making it suitable for use in environments where EMI is present.
- Stainless steel construction: The transmitter’s housing is made of stainless steel, which provides corrosion resistance and durability.
- Ease of installation: The Allen Bradley 836P-N2NMGB14A-D4 has a compact design that makes it easy to install in confined spaces.
Application
The Allen Bradley 836P-N2NMGB14A-D4 pressure transmitter is widely used in industrial processes and applications where precision pressure measurement is required. Some common applications include:
- Process control: The transmitter is used to monitor and control process parameters, such as pressure, temperature, and flow rate.
- Liquid and gas processing: The Allen Bradley 836P-N2NMGB14A-D4 can be used to measure pressure in various processing applications, such as petrochemical, chemical, and pharmaceutical industries.
- Food and beverage processing: The transmitter is suitable for use in food and beverage production, where the accuracy and reliability of pressure measurement are critical to ensure product quality and safety.
- Packaging and material handling: The Allen Bradley 836P-N2NMGB14A-D4 can be used to measure pressure in packaging and material handling systems, such as conveying systems, compression systems, and material handling equipment.
- Water and wastewater treatment: The transmitter is used to monitor and control water and wastewater treatment processes, where pressure measurement is necessary for ensuring treatment efficiency and preventing equipment failure.
Uses
Some specific uses of the Allen Bradley 836P-N2NMGB14A-D4 pressure transmitter in industrial processes and applications include:
- Level measurement: The transmitter can be used to measure the level of liquids or granular materials in storage tanks, silos, and vessels.
- Process monitoring: The Allen Bradley 836P-N2NMGB14A-D4 can be used to monitor various process parameters, such as pressure, temperature, and flow rate, to ensure that the process is operating within the desired range.
- Process control: The transmitter can be used to control process parameters, such as pressure, to maintain the desired process conditions.
- Alarm and shutdown: The Allen Bradley 836P-N2NMGB14A-D4 can provide an alarm or shutdown signal when the pressure measurement falls outside a desired range, which helps to prevent equipment failure and process upsets.
- Research and development: The transmitter can be used in research and development applications to test and evaluate new materials, processes, and equipment.
Maintenance
To ensure the proper operation and reliability of the Allen Bradley 836P-N2NMGB14A-D4 pressure transmitter, regular maintenance and calibration are necessary. This can include:
- Visual inspection: Regularly inspect the transmitter for any signs of damage or wear, such as cracks, corrosion, or loose connections.
- Cleaning: Clean the transmitter’s sensing elements and other components regularly to prevent the buildup of dirt, grit, and other contaminants that can affect the measurement accuracy.
- Calibration: Periodically calibrate the transmitter against a traceable standard to ensure that it is measuring pressure accurately. The frequency of calibration will depend on the application and process requirements.
- Testing: Perform functional testing of the transmitter to ensure that it is operating within the desired range and responding correctly to different input signals.
- Documentation: Maintain accurate documentation of the transmitter’s installation, configuration, and performance, including calibration data and test results.
- Replacement: Replace any defective or worn-out components, such as seals, gaskets, and electrical connections, as necessary.
As an electrical equipment supplier company called Techno Control Corporation, we are proud to provide the Allen Bradley 836P-N2NMGB14A-D4 pressure transmitter to industries all over Pakistan. Our commitment to quality, reliability, and customer service ensures that our customers receive the best possible products and services for their industrial automation and control needs.
Contact Information
Whatsapp: Contact
Contact Us: Go
Back to Blogs