Join our industrial newsletter for the latest in automation, power systems, and technical insights from TCC engineers.
By subscribing, you agree to our Privacy Policy and Terms of Service.
/4991049 - Fluke 710.webp)
The Fluke 710 (part 4991049) is an mA loop calibrator with built-in HART communication and valve test procedures that rate a smart control valve as good, marginal or bad.
It sources 4-20 mA while reading the valve's HART position and I/P pressure feedback, and runs signature, speed, step, manual and bump/partial stroke tests. As a loop calibrator it sources, simulates and reads mA and reads volts with 0.01% accuracy and 1 microamp resolution, has 24 VDC loop power and a selectable 250 Ohm HART resistor, logs up to 4910 records, and includes ValveTrack software.
/1734 B Fluke.webp)
Three-phase energy logger, 600 V CAT IV / 1000 V CAT III, 3 flexible probes, Fluke Connect
/2096379 - Fluke L210.webp)
Test probe LED light with 8 in probe extenders
/2679831 Fluke - 922 KIT.webp)
Airflow meter: pressure +/-4000 Pa, velocity 1-80 m/s, flow; kit with 12 in pitot tube
/2785725 Fluke - ESA620.webp)
Portable medical electrical safety analyzer, IEC 60601 / EN 62353, 20 A receptacle