Proline Promag D10 (10D) is an Endress+Hauser compact electromagnetic flowmeter designed exclusively for measuring the flow of conductive liquids in closed, fully filled pipes.
The measuring device is intended only for conductive liquids with a minimum conductivity of around 50 microsiemens per centimeter in closed pipes; any other use is outside the manufacturer's designated application. The sensor is rated to IP67 and, after mounting, retains that rating as long as cable entries are installed pointing downward with seals intact and unused entries plugged. Installation guidance calls for the sensor to sit in an ascending pipe section at least two pipe diameters from the nearest bend, avoiding the highest point of the line or a position just upstream of a free outlet in a vertical run where air can accumulate; partially filled pipes with a gradient require a drain-type configuration instead.